<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-01 04-19-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.50 MHz 5/5, 46 dBuV ISKELMA
Pilot RDS Phase Difference
4.3 kHz 1.8 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 46 kHz 15538 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,4 dBr 2,33 dBr 3,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 0 0 --:--
RT
-
AF EON
89.4, 92.5, 100.1, 107.7 MHz -
FM Scope Max at: 46 kHz MIN: 14 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/01 4.18.07 Total samples: 15538 Equivalent time: 0:12:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 3,1 dBr MIN: 1,4 dBr AVE: 2,33 dBr % above 12,2 dBr: 0,0 Last value: 2,1 dBr (2025/01/01 4.18.07) 04.04 04.06 04.08 04.10 04.12 04.14 04.16 04.18 -1 0 1 2 3 4 Pm [dBr]